My thunder

Lloyd Air Conditioner is so cool and Lloyd Air Conditioner is belonged to the Lloyd Air Conditioner company and Lloyd Air Conditioner auto switched cooling and hot because this design is different to another company designs.


Lloyd Air Conditioner is very comfortable air conditioner.I have this air conditioner and I use it a long time.


I think is so comfortable for us.I like the Lloyd Air Conditioner.This company’s Air Conditioner is very comfortable for all us.• During cooling: The preset temperature is lowered by 1°C at the start of SLEEP operation(when the timer is set). After that, the temperature


goes up by 1°C every an hour to become 1°C higher than


the present temperature.In ON TIMER operation, the unit starts the operation a little earlier, so


that the room can approach optimum temperature at ON time. This is


so called “Comfort start-up”.


• Mechanism


The room temperature is


checked 60 minutes before the


ON time. Depending on the


temperature at that time, the


operation starts 5 to 60 minutes


before the timer is at ON.


• The function is available for both


COOL and HEAT operation


mode(including AUTO). It does


not work for DRY mode.• During heating: The preset temperature is lowered by 1°C at the


start of SLEEP operation(when the timer is set). After that the temperature


becomes 3°C lower in an hour and 6°C lower in two hours


than the present temperature.• The unit draws heat from the cold outside air, transfers it to indoors and heats the room. As a characteristic of heat pump system, the


heating capacity reduces when the outside air temperature gets colder.


• It may take some time to supply hot air after turning on the air-conditioner.


• If the outside temperature becomes extremely low, it would be better to use an additional source of heating. Defrosting


If the outside temperature becomes low and humidity is high, the heat exchanger in the outdoor unit may frost over, which prevents


efficient heating.


If this happens, the automatic defrost function is activated and during defrosting the heating operation stops for 5 to 15 minutes


during defrosting.


• Both indoor and outdoor fans stop and the RUN light blinks slowly(1.5 sec. ON, 0.5 sec. OFF) during defrostin